Log |
On the tab, you can specify logging parameters of Agent and some Dr.Web Anti-virus components: •The parameter determines the level of detail of Agent logging (the dwservice.log and es-service.log files). •The parameter determines the level of detail of engine logging (engine logging data is written into the system log file). •The parameter determines the level of detail of Dr.Web updating module logging (the dwupdater.log file). •Enable the option to create memory dumps in case of scan errors. It is recommended that you enable this setting for Dr.Web operation errors analysis. •Enable the option to limit the number of log files, their size or the time of writing log data into each file. o—maximum number of log files (including the current and the archived) that will be stored. ▪Enable the option to archive old log files at rotation. o—rotation mode of the operation log. Select one of the following values: ▪ sets the limit on the size of each log file. —maximum allowed size of each log file. When the current file reaches the specified size, it is archived with the corresponding change of its name, and a new log file is created. ▪ sets the time limit on writing log data into each file. —maximum time of writing log data into each file. When the time reaches the specified duration, the file is archived with the corresponding change of its name, and a new log file is created. |