Dr.Web Server Remote Access

Top  Previous  Next

warning

For connection of the Server remote diagnostics utility, you must enable Dr.Web Server FrontDoor extension. To do this, in the Dr.Web Server configuration section, on the Modules tab, set the Dr.Web Server FrontDoor extension flag.

 

For connection of the Server remote diagnostics utility, administrator that connects via the utility, must have the Use additional features permission. Otherwise, access to the Server via the remote diagnostics utility will be forbidden.

To configure parameters for Server remote diagnostics utility

1.Select the Administrating item in the main menu of the Control Center, in the opened window, select Dr.Web Server remote access in the control menu.

2.Specify the connection protocol settings:

Set the Use TLS flag to enable connections of the remote diagnostics utility to Dr.Web Server via TLS protocol. If the flag is cleared, only TCP connections are allowed.
For TLS connection, specify the following settings:

Certificate—TLS certificate file which will be verified on connection. The drop-down list contains available certificates from the Server folder.

SSL private key—SSL private key file which will be verified on connection. The drop-down list contains available private keys from the Server folder.

In the Encryption key for TLS session tickets field, specify the path to encryption key for TLS session tickets. Used to resume a TLS session based on session tickets which are encrypted using the specified key.

Allowed cipher list – the string defining the list of ciphers from OpenSSL package that allowed for use in client connections. Leave the field blank to use the DEFAULT value that means ALL:!EXPORT:!LOW:!aNULL:!eNULL:!SSLv2.

3.Specify the connection hosts settings:

Address—IP address that is listened on the Server side for connecting the remote diagnostics utility.

Port—port that is listened on the Server side for connecting the remote diagnostics utility. The 10101 port is used by default.

To add one more connection interface, click icon-item-add and specify the values of added fields.

To forbid a connection from the previously allowed interface, remove it from the list by clicking icon-item-remove next to the line with this interface.

4.Click Save.

info