Update Restrictions for Workstations |
Via Dr.Web Security Control Center you can configure update mode for Dr.Web Enterprise Security Suite at protected workstations in particular time slots. To configure station update mode, perform the following actions: 1.Select the item in the main menu, in the opened window click the name of a station or group in the hierarchical list. Select in the control menu. 2.In the drop-down list, select the limitation mode: •—do not restrict distribution of updates on stations. •—forbid distribution of all updates on stations during time slots that are specified in the table below. •—forbid distribution of updates only for program modules during time slots that are specified in the table below. Virus bases updates will be performed with no changes in a normal mode. 3.Set the flag to limit the network traffic amount during transmitting of updates between Server and Agents. In the field, specify the value of maximal speed for updates transmission. 4.Set the flag to transmit all components updates to the stations not depending on the limitations that are specified in the Detailed Repository Configuration section. If the flag is cleared, station receives only those updates which are marked as current updates for distribution. 5.In the table, the update mode is specified using the following colors: ■green—update is enabled, ■red—update is disabled. The restrictions are set separately for each 15 minutes of each day of the week. To change the update mode, click the corresponding block of the table: •To change the update mode for a row (full day), click the corresponding color in the right part of the table row. •To change the update mode for a column (a particular 15 minutes interval of each day of the week), click the corresponding color under the table column. 6.After editing, click to accept changes. In the toolbar, the following options to manage the section content are also available: —restore the values that all parameters in this section had before current editing (last saved values). —restore default values of all parameters in this section. —copy settings from this section to settings of other station, group or several groups and workstations. —remove personal settings of a station and set inheritance of settings in this section from a primary group. —copy settings of this section from a primary group and set them for selected stations. Inheritance is not set and stations settings considered as a personal. —save all settings from this section to a file of a special format. —replace all settings in this section with settings from the file of a special format. |